FAILURE 300-353: MITSUBISHI INVERTER ALARM MESSAGE
Always make sure you have the correct Frequency Inverter Parameter settings in the Inverter, especially when you have replaced the Inverter.
If unsure go to the Configuration Menu and select "Inverter Menu...", set the correct Machine Type and supply voltage; then load the
parameters from the washer computer to the Inverter again. If the correct parameters are not in the Frequency Inverter all sorts of Inverter
alarms may occur. See also the Frequency Inverter manual (available on request) for more info.
Err N°
Failure
300
Err OC1
301
Err OC2
302
Err OC3
303
Err OV1
304
Err OV2
305
Err OV3
306
Err THT
307
Err THM
308
Err FAN
309
Err OLT
310
Err BE
311
Err GF
312
Err OHT*
313
Err OPT
314
Err PE
315
Err PUE
316
Err Ret*
317
Err CPU
318
Err E.6
319
Err E.7
320
Err IPF
321
Err UVT
322
Err LF
323
Err OP1*
324
Err OP2*
325
Err OP3*
326
Err CTE
327
Err P24
*: This option or function is not used. If you have this error anyway do the following:
1) Reload the Frequency Inverter Parameters.
2) If the fault is persistent, replace the Frequency Inverter.
Failure Name
Failure Name:
Overcurrent
See detailed explanation on following pages.
Overcurrent
See detailed explanation on following pages.
Overcurrent
See detailed explanation on following pages.
Overvoltage
See detailed explanation on following pages.
Overvoltage
See detailed explanation on following pages.
Overvoltage
See detailed explanation on following pages.
Inverter overload
See detailed explanation on following pages.
Motor overload
See detailed explanation on following pages.
Fan stopped
Repair the cooling fan (clean or replace if necessary).
Stall prevention
See detailed explanation below.
Brake transistor
Short circuit in brake transistor circuit. Power off immediately!
Replace the Inverter.
Ground fault
Output overcurrent to ground.
1) Check the motorcable and motor for ground faults.
2) Disconnect the motorcable and try again. If you still have the error,
replace the Inverter.
Ext thermal relay
External thermal relay (TRM module, see electrical scheme) for
motor protection tripped. TRM module was only used on certain
washers with MCB controller and A500 Inverter.
Option
See detailed explanation below.
Corrupt memory
Memory was overwritten too many times. Replace Inverter.
PU leave out
See detailed explanation below.
Retry no over
The max number of retries after fault reached. The actual Inverter error
code that causes the problem and which should be solved, is stored
just before Err 316 in the error log.
CPU Fault
Communication error of built in CPU. Replace Inverter.
CPU Fault 6
Internal fault. If the fault is persistent, replace the Inverter.
CPU Fault 7
Internal fault. If the fault is persistent, replace the Inverter.
Instantaneous power
Power failure between 15 and 100ms. Check for bad contacts in
failure
the power circuit. Repair the power supply.
Under voltage
Supply voltage too low. Check jumper P/+-P1.
Output phase failure
Phase open detected on Inverter output. Check for bad contacts or
defect (open) motor windings.
Option slot 1
Problem with the option in slot 1 or option contact fault
Option slot 2
Problem with the option in slot 2 or option contact fault
Option slot 3
Problem with the option in slot 3 or option contact fault
PU short circuit
Short circuit on the RS485 communication connector.
Check for short circuit in the communication cable.
24VDC short circuit
Short circuit on the 24VDC power output (PC terminal).
Check for short circuit on the Inverter control terminals.