The Cool Down Sequence
Prewash
Wash
n After a hot wash you can program a Cool Down Sequence to avoid temperature shock and shrinking of the garments.
n The drain step after the hot wash must be put on NO DRAIN.
n No inlets are programmable:
– Washer with 2 water inlets: inlet 1 is the standard inlet.
n The water level cannot be programmed as the process of adding and draining water does not allow this.
IMPORTANT: Do not program a drain sequence before a cool down sequence.
Menu Item
Temperature
RPM
Drain Valve
On Time
Off Time
Time
Signal
Cool Down
Rinse
Description
The water temperature
The suggested RPM depends on the Machine Type.
Only available on washers with both a normal Open and
normal Closed Drain valve.
The wash action, motor On Time.
Gentle wash action: 3 sec.
(The suggested default values can be adjusted in the
Initialization Menu)
The wash action, motor Off Time.
Gentle wash action: 12 sec.
(The suggested default values can be adjusted in the
Initialization Menu)
The programmed time = time needed to decrease the
water temperature.
Once the programmed temperature has been reached,
the next Sequence will be started.
(for 0 minutes the Cool Down sequence will be skipped)
(programmable in steps of 0.5 minutes)
IMPORTANT: If a short time is programmed, the water
temperature will decrease fast.
Recommendation: Program 1 minute for each 37.4°F (3°C)
temperature drop.
Example: For a hot wash of 194°F (90°C) and a Cool Down
Sequence of 140°F (60°C) a time of about 86°F (30°C)/
37.4°F (3°C) = 10 minutes should be programmed for the Cool
Down Sequence.
When a signal is programmed, a pause will be introduced at
the end of the Wash Step. This allows the operator to add
soap for the next step. A buzzer signal warns the operator
that the cycle has been interrupted.
Final Rinse
Soak
Spray
No Wash
Default
Limits
140°F
33.8–140°F
(60°C)
(1–60°C)
1
1–2
12 sec
1–99 sec
3 sec
1–99 sec
7 min
0–99.5 sec
No
No/Yes
27