Toolbox Menu
The purpose of the Toolbox Menu is to give support at technical interventions.
Menu Item
View Input States ?
1 Input 1
20 Input 20
Imbalance Statistics ...
Imbalance ...
1 ...0,5 0
...
31 > 15 0
Current ...
1 I0 0
...
4 I3 0
Inverter Power
Reset Service Counts
RTC Time
RTC Date
Adjust Clock
Hour
Minutes
Day
Month
Year
Exit
52
On
Off
Off
No
XX:YY:ZZ
AA:BB:CC
XX
YY
AA
BB
CC
Description
The Input states for Input 1, ..., Input 20.
The exact function of the inputs can be found on the electrical schematic
of the Washer Programmer.
– if the Input state is Off, the Input signal is low.
– if the input state is On, the Input signal is high.
Diagnostic information on imbalance of the washer.
With this function it is possible to switch on the power of the Inverter if a
Technical Intervention is needed.
ATTENTION: Special care has been taken at the initialization of the
parameters of the Frequency Inverter. Maytag is not responsible for poor
performance of the washer if the owner has installed new parameter settings
in the Inverter that do not correspond with the original settings at the factory.
Once the washer has reached the total number of wash cycles like those set
at the "Service Interval," a signal is given at the end of each cycle until the
Cycle Counter has been reset.
The Time value of the Real Time Clock.
XX: Hours, YY: Minutes, ZZ: Seconds
The Date value of the Real Time Clock.
AA: Day, BB: Month, CC: Year
Set the correct Date and Time for the RTC.
Return to Service Menu.