Appendix | ASCII Communication with Sensor

A 2.4.21 Output Data Rate

Reduces the measured value output for all available interfaces.
- 1: Output of every measured value
- 2 ... 1000: Output of each n-th measured value
Default = 1 NONE

A 2.4.22 Scale Output Values

Sets the scaling of the C-BOXVALUE via USB.
The default scaling is for distance/level 0 to MR (Sensor 1) and for thickness measurement 0 to MR (Sensor1)
+ MR (Sensor2) (MR=Measuring range).
The minimum and maximum measured value must be indicated in millimeters. The available output range
of the USB output is then spread between the minimum and maximum measured value. The minimum and
maximum measured value must lie between -1024.0 and 1024.0 mm with 4 decimal places. The maximum
value must be larger than the minimum value.
Default = STANDARD 0.0 50.0

A 2.4.23 Error Processing

Setting the behavior of the measured value output in case of error for the C-Box/2A measured value, not for
the sensor values.
- NONE: No holding the last measured value, output of error value.
- 0: Infinite holding of the last measured value
- Number: Holding the last measured value on the number of measuring cycles; Then an error value (maxi-
Default = NONE
C-Box/2A
OUTREDUCE <Output reduction> ([ANALOG] [USB] [ETHERNET])|NONE
OUTSCALE_RS422_USB STANDARD|(TWOPOINT <Minimum measured value> <Maximum mea-
sured value>)
OUTHOLD NONE|0|<Number>
mal 1024) is output.