Appendix | ASCII Communication with Sensor
Value
Sensor 1 Value,
Sensor 2 Value,
C-Box Value
Fig. 46 Error ranges (raw values)
Value
C-Box Value
C-Box Time-
stamp
C-Box Counter
C-Box Digital
Fig. 47 Calculation of the values
C-Box/2A
Interface
USB
Ethernet: INT_MAX -10 ... INT_MAX
Interface
Calculation
USB
Digital * (C-Box Range Max - C-Box Range Min)
Value =
Ethernet
Digital
Value =
1.0e+006
USB
Digital (Left shift by 8 bits)
Value =
Ethernet
Digital (unsigned int)
Value =
USB
Digital
Ethernet
Digital (unsigned int)
, see
Fig. 48
Value range
262073 ... 262143
2147483637 ... 2147483647
131072.0
1.0e+006
1.0e+006
Unit
[mm]
+ C-Box Range Min
[mm]
[s]
[s]
without
without