Operation
Trigger mode
You may select under
Chap. 5.5.13.
Trigger mode
Fields with a grey
background re-
quire a selection.
Dark bordered
fields require the
Value
specification of a
value.
C-Box/2A
Current
No synchronization
synchroniza-
Internal synchronization
tion mode
External synchronization
Change synchronization mode
Selected
No triggering
mode
Level-triggering
Edge-triggering
Software triggering
among the 3 synchronization options, see
There is a continuous measured value
output as long as the selected level is
applied. The data output stops after-
wards. The trigger can be set to high
level / low level.
The sensor outputs the previously
set number of measured values or
initiates a continuous measured value
output after the trigger event. The
trigger can be set to the rising edge /
falling edge.
A measured value output is started as
soon as a software command is trig-
gered. The trigger moment is defined
more inexactly. The sensor outputs
the previously set number of mea-
sured values or initiates a continu-
ous measured value output after the
trigger event.