Meters; Meter Installation; Speedometer Tube Installation - HONDA marine BF200A Set-Up, Installation, And Pre-Delivery Service

Hide thumbs Also See for BF200A:
Table of Contents

Advertisement

METERS
Meter Installation
Meters and other instruments should be installed on the
instrumentlrnounting panel. If any other location is selected,
it w i l l be necessary t o use a mounting plate w i t h a
thickness of 2 - 11 mm (1/16 - 7/16 in).
If mounting plate thickness exceeds 11 rnrn (0.4 in), the
mounting bracket must be modified accordingly.
Tighten the mounting nuts evenly on both sides.
Meter installation angle should be within 45" - 75".
If the boat has a magnetic compass, install the tachometer
a minimum of 130 m m (5 in) away from the compass.
Installation hole diameter:
Tachometer:
Trim meter:
Speedometer:
Hour meter:
Voltmeter:
0
80.5 mm (3.2 in)
0
52.5 mrn (2.1 in)
0
86.5 m m (3.4 in)
0
54.0 m m (2.1 in)
0
54.0 m m (2.1 in)
MOUNTING NUT ( 2 1
B
RECOMMENDED
C
O
N
ANGLE:
45"
-
75"
Speedometer Tube Installation
Cut off about
3
mm (1/8 in) of the nipple end of the
outboard motor sensor, then insert i t i n t o the
speedometer tube. Attach securely with a clamp.
SPEEDOMETER
TUBE
.
, ,
Route the tube through the clamp bracket as shown.
Secure the tube to the boat hull in such a way that the
tube cannot be cut, bent or crushed. Then, route the tube
to the speedometer.
If the sensor opening is plugged with salt or a foreign
object, remove it with a piece of wire, etc.
When the boat is stored, remove the water in the sensor
tube.
Before the final tube attachment, make sure the tube is
not pulled too tight or crushed when the motor is tilled UP
or DOWN or turned fully to the right or left.
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bf175aBf225a

Table of Contents