Fddi Port Lercutoff; Fddi Port Label; Setting Port Labels - 3Com SUPERSTACK 2200 User Manual

Switch administration console
Table of Contents

Advertisement

8-22
C
8: A
HAPTER
DMINISTERING
Top-Level Menu
system
ethernet
station
fddi
display
path
bridge
lerAlarm
mac
ip
lerCutoff
port
snmp
label
analyzer
path
script
logout

Setting Port Labels

Top-Level Menu
system
ethernet
station
fddi
display
path
lerAlarm
bridge
mac
ip
lerCutoff
port
snmp
label
analyzer
path
script
logout
FDDI R
ESOURCES
To set the lerCutoff:
1 From the top level of the Administration Console, enter:

fddi port lerCutoff

You are prompted for a port number and an estimated link error rate value
at which the link connection will be broken.
2 Enter the port number.
3 Enter the estimated link error rate value.
Valid exponent values are -4 through -15. Even though these are negative
exponents, enter the value without the negative symbol. For example, to
express the value 1 x 10
Port labels serve as useful reference points and as an accurate means of
identifying your ports for management. You may want to label your FDDI
ports for easy identification of the devices attached to them (for example,
workstation, server, FDDI backbone).
To label an FDDI port:
1 From the top level of the Administration Console, enter:

fddi port label

You are prompted for a port number and a label value.
2 Enter the port number.
3 Enter the label value.
-7
, enter 7 as the value.