Rate Meter Setup | Solids (Generic Wizard) - FARMSCAN Jackal v2 General Description Manual

Area-, batch-,tacho-meter rate-, spray-, pressure-, surveillance-, wheel slippage- monitor
Hide thumbs Also See for Jackal v2:
Table of Contents

Advertisement

28

Rate Meter Setup | Solids (Generic Wizard)

RATE METER SETUP | SOLIDS (GENERIC WIZARD)
The Jackal can be configured to monitor solid products. If only one input
is used the main screen will display the flow information in kg, lb, kg/s,
kg/hr, T/hr, lb/s. If using the speed & area function the Jackal can also display
kg/Ha, bu/ac, T/Ha.
Refer to
(PAGE
31) for Rate Monitor setup to display kg/Ha
Sensors Required
Shaft sensor kit (2076 Slow /2077 Fast) (2 wire) or
Proximity sensor kit (2010P) (3 wire)
Available Connections
This setup section assumes that physical wiring for the required sensors have been
completed.
If not please refer to
PAGE 7
SETUP
1. Ensure there is product in bin/tank
2. Have a bucket ready to catch the product
3. Have a set of scales (e.g. Farmscan Ag Part # 2199) ready to weigh the product
From the front screen press
SETUP
Enable the input by pressing
EDIT
September 2015
(PAGE
4)
on wiring requirements
Highlight WIZARD & press
SELECT
Choose your unit of pulse.
pulse/kg or pulse/lb
www.farmscanag.com
Highlight GENERIC WIZARD
& press NEXT
Highlight TARGET & press
EDIT
Highlight the INPUT number
X: the sensor wire is
connected into on the rear
of the Jackal & press NEXT
Using the NAV buttons enter
the target amount (kg) to be
measured. i.e. 10.0000
Press EXIT when done.
AM-JACKAL-3

Hide quick links:

Advertisement

Table of Contents
loading