Connections
9
BATCH (SOLENOID)
(1501)
When using the Jackal as a batch meter with liquid ensure the
appropriate flow meter is setup as per
PAGE
24.
Any 12v solenoid can be connected to the Jackal to control
flow. Ensure you are using the ground/earth (A1) terminal. If
the terminal already has a wire from another sensor applied to
it then you will need to piggy back onto this wire. Insert the
trigger wire into the Solenoid/Shutoff output (OUT1/B8)
REMOTE RUN/HOLD
Jackal version 2 & above can connect an external run/hold
trigger wire into any unused port. i.e. – Jackal can be remotely
placed on hold or run mode from an external source or switch
without having to press the Run/Hold button on the Jackal
itself. Please note that this is normally run through an
automotive relay.
Ensure you are using the ground/earth (A1) terminal. If the
terminal already has a wire from another sensor applied to it
then you will need to piggy back onto this wire. Insert the
trigger wire into an available port.
Enable the remote run/hold via Front Screen > Setup > Other
Settings > Extern. Run/Hold.
Refer to OTHER SETTINGS section in this manual for further explanation.
(PAGE
43)