Prime the Bin/Tank until
product flows & then stop it.
Press START on the Jackal,
Run Bin & let product flow.
This will allow pulses from the
sensor to register and the
number of pulses will be
displayed next to
Meas.pulses:
Using the NAV buttons select
how you would like the Unit
Of Display to be displayed on
the front screen. I.e. kg
Press NEXT
You will be returned to the
Setup Screen.
Press EXIT
September 2015
When the scales measure the
desired test volume, i.e.
10kg, stop the Bin/Tank.
Press STOP
You have the option to set
Alarm Min/Max points if
required. Using the NAV
buttons select & EDIT as
required. Press NEXT
Example: 1UP
Accumulation of Kg
THIS ENDS THE AUTO SETUP FOR RATE METER SETUP
REFER TO
PAGE 32
TO SETUP AS RATE MONITOR kg/Ha
www.farmscanag.com
Rate Meter Setup | Solids (Generic Wizard)
Press CALC. This will divide
the measured amount by the
number of pules registered.
Name the input if you desire,
Press EDIT
or Press NEXT
MANUAL RATIO will now be
updated to reflect the
calibration factor.
Press NEXT
It's recommended to do this
test 3 times to get an
average pulse count per kg.
The Wizard is now complete.
Press NEXT