Other Settings (Manual Setup) - FARMSCAN Jackal v2 General Description Manual

Area-, batch-,tacho-meter rate-, spray-, pressure-, surveillance-, wheel slippage- monitor
Hide thumbs Also See for Jackal v2:
Table of Contents

Advertisement

OTHER SETTINGS (MANUAL SETUP)

Other settings is used to setup Implement width for displaying Ha,Ac, Enable/Disable remote run/hold function,
audible alarm notifications & language control.
FRONT SCREEN > SETUP > OTHER SETTINGS
If you wish to display Ha/Ac on the front screen you need to have an implement width set.
You can adjust the implement with and choose your UOM (m, ft, yd, in, km, mi).
If the UOM & implement widths remain untouched the Jackal will not display the information unless specified in the FRONT
The EXTERNAL RUN/HOLD function can be used to enable/disable all accumulating values and alarms set in the Jackal
NOTE – When the EXTERNAL RUN/HOLD is active on ANY input the function of the RUN /HOLD button on the front screen is
The trigger wire can be applied to any of the 13 available inputs on the Jackal. To enable maximum flexibility for this function
NORMALLY ON or NORMALLY OFF mode can be selected for this function.
When a circuit exists between the selected input and ground
(GND), selecting NORMALLY ON will result in the Jackal
going into HOLD mode
After you select the desired hold method select the INPUT# port that is being used to detect Run/hold
September 2015
By default the Jackal displays 8m.
without pressing the RUN/HOLD on the Jackal itself.
DISABLED: External Run/Hold is not used. Use the Run/Hold button only.
www.farmscanag.com
SCREEN setup.
disabled.
Selecting NORMALLY OFF will result in the reverse i.e. the
Jackal will be in RUN mode until the circuit is broken after
which it will go into HOLD mode.
Other Settings (Manual Setup)
AM-JACKAL-3
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents