Using The Wizard - FARMSCAN Jackal v2 General Description Manual

Area-, batch-,tacho-meter rate-, spray-, pressure-, surveillance-, wheel slippage- monitor
Hide thumbs Also See for Jackal v2:
Table of Contents

Advertisement

14

Using the Wizard

USING THE WIZARD
The Jackal has an inbuilt wizard function for common tasks.
Current Wizards include easy setup for:
a. Area/Speed Wheel
b. Area/Speed GPS
c. TachoMeter
There is an setting called VeryLowSpeed : for slow shaft/pulse speed when setting up shaft/pulse inputs. This is for shaft
speeds of 1 rpm to 20 rpm. When this setting is turedn on for the input it extends the sample time and will steady the
reading for slow rpm/pulses. If turned on for higher speed rpm/pulses the display will take longer to respond changes in
speed.
d. FlowMeter
e. Slippage Meter
f.
Generic Wizard
Step 1
Press SETUP button
Step 2
Highlight Wizard
with the UP/DOWN
NAV buttons and
press the SELECT
button
Step 3
Select the
appropriate Wizard
with the UP/DOWN
NAV buttons and
press the NEXT
button
September 2015
Wheel pickup & sensor required
No Wheel Sensor required, GPS input only
rpm / Count (sensor required).
Direct readout or batch (flowmeter required)
GPS v Wheel Input (sensor required)
You can choose the input, screen position & calibration factors
NB : During the wizard if you make a mistake press
EXIT to go back one page
www.farmscanag.com