Air/Volt/Depth/%/Temp Pressure Sensor
CALIBRATION (LIVE READOUT)
The Jackal also allows for a semi-automatic setup when the voltage values are unknown for a particular voltage
input. A live voltage readout is displayed in the top left hand side when the sensor is active.
Follow the previous 5 steps followed by :
Press EDIT to change the
unit. kPa,psi,bar,Volt,%,˚C.
i.e. kPa
Highlight or confirm the UOD
(Unit of Display)
e.g. kPa
Press NEXT when done
You will be returned to the
Setup Screen.
Press EXIT
September 2015
Engage the implement
and/or adjust the pressure
manually to the low point the
sensor will need to operate
in.
You have the option to set
Alarm Min/Max points if
required. Using the NAV
buttons select & EDIT as
required. Press NEXT
Example: 1UP Display of
kPa
THIS ENDS THE SETUP FOR A VARAIBLE VOLTAGE INPUT SENSOR
www.farmscanag.com
The voltage will now be
displayed. e.g. 1.75v.
In the above example we can
set the minimum of 1kPa by
HIGHLIGHTING & EDITTING
the values as required.
Press SET. This will copy the
live voltage into the CAL LOW
voltage point
Name the input if you desire,
Press EDIT
or Press NEXT
Repeat the previous 2 steps
for the CAL HIGH values
The Wizard is now complete.
Press NEXT