BIN LEVEL SENSOR

The Jackal can be configured with a bin level sensor for detecting empty/full
Sensors Required:
Bin Level Sensor (A-2220P/2060)
Any other style (High/low) or (On/Off) or (Empty/Full)
Available Connections
(PAGE
This setup section assumes that physical wiring for the required sensors have been
completed. If not please refer to
SETUP
From the front screen press
SETUP
Enable the input by pressing
EDIT
Highlight the Unit of Display
that you wish to be displayed
on the front screen.
Press NEXT
September 2015
4)
PAGE 8
on wiring requirements
Highlight WIZARD & press
SELECT
Press EDIT to change the
unit. Full/Empty, H/L
(high/low), On/Off
You have the option to set
Alarm Min/Max points if
required. Using the NAV
buttons select & EDIT as
required.
Press NEXT
THIS ENDS THE SETUP FOR A BIN LEVEL SENSOR
www.farmscanag.com
Highlight GENERIC WIZARD &
press SELECT
State will updated "Live" For
example. Low = bin empty,
High = bin full. Test by placing
hand around sensor.
Name the input if you desire,
i.e. BIN1.
Press EDIT
or Press NEXT.
Wizard is now complete.
Press NEXT
Bin Level Sensor
Highlight the INPUT number
(9-13) to where the sensor
wire is connected into on the
rear of the Jackal & press
NEXT
Highlight Level & select
LEVEL. This can be changed
from Normal to Invert. (Can
be used if Full/empty is
reversed) Press NEXT
Press EXIT to return to the
front screen
AM-JACKAL-3