CALIBRATION (AUTO SET)
1. Ensure tank has water & pump is ready
2. Have a bucket ready to collect the water
3. Have a measuring device to measure the amount of liquid
Highlight TARGET & press
EDIT
Press CALC. This will divide
the measured amount by the
number of pules registered.
Name the input if you desire,
Press EDIT
or Press NEXT
September 2015
Using the NAV buttons enter
the target amount (L) to be
measured. i.e. 20.0000
Press EXIT when done.
MANUAL RATIO will now be
updated to reflect the
calibration factor.
Press NEXT
The Wizard is now complete.
Press NEXT
THIS ENDS THE AUTO SETUP WIZARD FOR FLOW METER
REFER TO
PAGE 31
TO SETUP AS RATE MONITOR L/Ha
www.farmscanag.com
Press START, & let water flow.
This will allow pulses from the
flow meter to register and
the number of pulses will be
displayed next to
Meas.pulses:
Using the NAV buttons select
how you would like the UOD
to be displayed on the front
screen.
Press NEXT
You will be returned to the
Setup Screen.
Press EXIT
Flow Meter Setup (Wizard)
When the desired test
volume has been reached
press STOP
You have the option to set
Alarm Min/Max points if
required. Using the NAV
buttons select & EDIT as
required. Press NEXT
Example: 1UP monitoring
Flow Meter in L/Min
AM-JACKAL-3
25