Air/Volt/Depth/%/Temp Pressure Sensor - FARMSCAN Jackal v2 General Description Manual

Area-, batch-,tacho-meter rate-, spray-, pressure-, surveillance-, wheel slippage- monitor
Hide thumbs Also See for Jackal v2:
Table of Contents

Advertisement

34

Air/Volt/Depth/%/Temp Pressure Sensor

AIR/VOLT/DEPTH/%/TEMP PRESSURE SENSOR
The Jackal can be configured to read & display a pressure sensor, voltage,
percentage, temperature and display:
kPa, psi, bar, Volt, %, ˚C
Sensors Required:
AA-119H or AA-119L (pressure)
Any other style that outputs a voltage. i.e. Position sensor (AA-430)
for displaying depth as a percentage (%)
Available Connections
This setup section assumes that physical wiring for the required sensors have been completed.
If not please refer to
PAGE 8
CALIBRATION (MANUAL)
The example below details setting up a LIQUID PRESSURE SENSOR.
From the front screen press
SETUP
Enable the input by pressing
EDIT
September 2015
(PAGE
4)
on wiring requirements.
Highlight WIZARD & press
SELECT
Press EDIT to change the
unit. kPa,psi,bar,Volt,%, ˚C.
i.e. kPa
www.farmscanag.com
Highlight GENERIC WIZARD &
press SELECT
st
Highlight the 1
CAL HIGH
value and EDIT the field to
set the maximum the device
will be able to display. I.e.
600kPa. Current input
voltage of input is displayed
in the top left corner.
NB : If manufacture values
are not available, please
refer to
PAGE 36
for further
instructions
Highlight the INPUT number
(7-8) to where the sensor
wire is connected into on the
rear of the Jackal & press
NEXT
.
Using the manufactures
guide set the maximum
voltage of the sensor.
e.g. 5.000v by pressing EDIT
AM-JACKAL-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents