Change Parameter Settings - YASKAWA CIPR-GA70C Series Initial Steps

High performance type
Hide thumbs Also See for CIPR-GA70C Series:
Table of Contents

Advertisement

11 Drive Start-Up
Mode
T1-01
Rotational Auto-
0
Tuning
Stationary Auto-
1
Tuning 1
Stationary Line-
2
Line Resistance
Mode
T4-01
Motor Parameter
0
Setting
Line-to-Line
1
Resistance

Change Parameter Settings

The procedure below shows how to change the C1-01 [Acceleration Time 1] setting. Use this procedure to set
parameters for other applications
1.
Push
(Home) to show the HOME screen.
Note:
• The keypad will show [Home] in the top right corner when the HOME screen is active.
• If [Home] is not on
2.
Push
(Menu).
3.
Push
or
EN 24
Table 11.1 Auto-Tuning Mode Selection
Application Conditions and Benefits
Recommended tuning mode for the most accurate results. Select this tuning mode
when:
• Users can decouple the motor from the load.
• Users cannot decouple the motor from the load, but the motor load is less than
30%.
Automatically calculates motor parameters for vector control. Select this tuning
mode when:
• Users cannot decouple the motor from the load.
• The motor test report data is not available.
Select this tuning mode when:
• The drive and motor capacities are different.
• The drive is in V/f Control.
• Replacing the drive and motor.
Table 11.2 EZ Tuning Mode Selection
Application Conditions and Benefits
Sets motor parameters.
Select this tuning mode after replacing the drive, motor, and motor cables.
, push
(Back).
to select [Parameters], then push
.
YASKAWA ELECTRIC TOEP C710617 17D YASKAWA AC Drive GA700 Initial Steps
A1-02 [Control
Method
Selection]
0
2
[V/f]
[OLV]
-
YES
-
YES
YES
YES
A1-02 = 8
[EZOLV]
YES
YES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga700

Table of Contents