Start-Up Procedure - YASKAWA CIPR-GA70C Series Initial Steps

High performance type
Hide thumbs Also See for CIPR-GA70C Series:
Table of Contents

Advertisement

8

Start-Up Procedure

1. Install and wire the drive.
2. Energize the drive.
3. Use A1-06 [Application Preset] to initialize the drive for a special application if necessary.
4. Run the Setup Wizard to automatically set these functions:
• Control method selection
• Duty rating selection
• Monitor parameters
• Speed reference source
• Run command source
• Acceleration and deceleration times
5. Run the motor without a load.
6. Make sure that the drive is operating correctly and make sure that the host controller is sending commands to
the drive.
7. Connect the load.
8. Run the motor.
9. Make sure that the drive is operating correctly.
10. Fine-tune and set application parameters, such as PID.
11. Check final operation and make sure that parameter settings are correct.
The drive is prepared to run the operation.
YASKAWA ELECTRIC TOEP C710617 17D YASKAWA AC Drive GA700 Initial Steps
Figure 7.1 LED Flashing Statuses
/
Figure 7.2 Relation between RUN LED and Drive Operation
8 Start-Up Procedure
EN 11
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CIPR-GA70C Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ga700

Table of Contents