Faults and Alarms

Look at the drive keypad for fault and alarm information if the drive or motor do not operate correctly.
For drive alarms:
• Keypad shows the alarm code
and ALM/ERR on the LED Status Ring flash.
• The drive will continue to operate the motor. Some alarms let the user select a motor stopping method.
For drive faults:
• Keypad shows the fault code
and ALM/ERR on the LED Status Ring stay illuminated.
• The drive shuts off output, the fault relay output turns ON, and the motor coasts to stop.

Fault Reset Procedure

1. Remove the cause of the fault or alarm.
2. Push
(Reset) or
This table lists the most frequent alarms and faults with possible causes and solutions.
Refer to the Technical Manual for a full list of faults and alarms.
Code
Name
bb
Baseblock
CrST
Remove RUN Command to
Reset
YASKAWA ELECTRIC TOEP C710617 17D YASKAWA AC Drive GA700 Initial Steps
Sets the bias of the Ux-xx monitor signal in H4-01 [Terminal FM Analog Output Select].
Sets which drive monitor Ux-xx to output from MFAO terminal AM.
Sets the gain of the Ux-xx monitor signal in H4-04 [Terminal AM Analog Output Select].
Sets the bias of the Ux-xx monitor signal in H4-04 [Terminal AM Analog Output Select].
Sets the output signal level from MFAO terminal FM.
0: 0 to 10 Vdc, 1: -10 to +10 Vdc, 2: 4 to 20 mA
Sets the output signal level from MFAO terminal AM.
0: 0 to 10 Vdc, 1: -10 to +10 Vdc, 2: 4 to 20 mA
Sets the motor overload protection function that uses electronic thermal protectors.
0: Disabled, 1: Variable Torque, 2: Constant Torque 10:1 Speed Range,
3: Constant Torque 100:1 SpeedRange, 4: PM Variable Torque, 5: PM Constant Torque,
6: Variable Torque (50Hz)
Sets the motor overload (oL1) protection time. Usually it is not necessary to change this
setting.
Sets the method that the drive will use to prevent overvoltage faults when decelerating.
0: Disabled, 1: General Purpose, 2: Intelligent (Ignore Decel Ramp),
3: General Purpose w/ DB resistor, 4: Overexcitation/High Flux,
5: Overexcitation/High Flux 2
on the keypad while the keypad is showing the fault or alarm code.
Causes
A digital input set for the software
baseblock function is OFF and the drive
will not accept a Run command.
Tried to reset a fault when a Run
command was active.
13 Faults and Alarms
Description
Possible Solutions
• Make sure that the digital input function
selections are correct.
• Make sure that the host controller sequence is
correct.
Stop the Run command and reset the drive.