Application I/O
In addition to the standard I/O, the application I/O provides the inverter with more digital and
analog inputs and is intended for individual applications. The combination with network com-
ponents is not available.
Digital inputs
Digital outputs
Analog inputs
Analog outputs
24-V input
10-V output
24-V output
Reference potential
Connection system
214
+24 V
100 mA
Terminal X3: DI1, DI2, DI3, DI4, DI5, DI6, DI7
Terminal X3: DO1, DO2
Terminal X3: AI1, AI2
Terminal X3: AO1, AO2
Terminal X3: 24E
Terminal X3: 10V
Terminal X3: 24V
Terminal X3: GND
pluggable spring terminal
Applica on I/O
+10 V
DI3/DI4 can be optionally used as frequency or
encoder input.
HIGH active/LOW active switchable
can be optionally used as voltage or current input.
Can be optionally used as voltage or current output.
Mains-independent DC supply of the control electron-
ics (incl. communication)
Reference voltage or setpoint potentiometer