Information on project planning

Project planning process

Dimensioning

3 methods for dimensioning
Fast: Selection of the inverter based on the motor data of a 4-pole asynchronous motor.
Detailed: In order to optimise the selection of the inverter and all drive components, it is
worth to execute the detailed system dimensioning based on the physical requirements of the
application. For this purpose, Lenze provides the «Drive Solution Designer» (DSD) design pro-
gram.
Manual: The following chapter guides you step by step to the selection of a drive system.
Workflow of a configuration process
Define required input variables
Operating mode
Max. load torque
Max. load speed
Min. load speed
Site altitude
Temperature in the control cabinet
Define required input variable
Calculate range of adjustment and determine rated point
Determine motor based on the rated data
Define correction factors for the inverter
Determine inverter based on the rated data
Check motor/inverter combination
Determine brake resistance
Final configuration
S1 or S6
M
Nm
L,max
n
rpm
L,max
n
rpm
L,min
H
m
T
°C
U
Information on project planning