Enclosures - Lenze i550 Series Project Planning Manual

Cabinet 0.25...132 kw
Hide thumbs Also See for i550 Series:
Table of Contents

Advertisement

Appendix
Glossary

Enclosures

The degree of protection indicates the suitability of a motor for specific ambient conditions
with regard to humidity as well as the protection against contact and the ingress of foreign
particles. The degrees of protection are classified by EN 60529.
The first code number after the code letters IP indicates the protection against the ingress of
foreign particles and dust.The second code number refers to the protection against the ingress
of humidity.
Code number 1 Degree of protection
0
No protection
1
Protection against the ingress of foreign particles d >
50 mm. No protection in case of deliberate access.
2
Protection against medium-sized foreign particles,
d > 12 mm, keeping away fingers or similar.
3
Protection against small foreign particles d > 2.5 mm.
Keeping away tools, wires or similar.
4
Protection against granular foreign particles, d > 1 mm,
keeping away tools, wire or similar.
5
Protection against dust deposits (dust-protected), com-
plete protection against contact.
6
Protection against the ingress of dust (dust-proof),
complete protection against contact.
Glossary
Abbreviation
AIE
AIS
OFF state
CCF
EC_FS
EC_SS1
EC_SS2
EC_STO
ON − status
FIT
FMEA
FSoE
GSDML
HFT
Cat.
OSSD
PELV
PL
PM
PP
PS
PWM
SCS
SD−In
SD−Out
SELV
SFF
SIL
262
Code number 2 Degree of protection
0
1
2
3
4
5
6
Meaning
Acknowledge In Error
Acknowledge In Stop
Signal status of the safety sensor when it triggers or responds
Common Cause Error (also β-value)
Error Class Fail Safe
Error Class Stop 1
Error Class Stop 2
Error Class Stop 0
Signal status of the safety sensor in normal operation
Failure In Time, 1 FIT = 10-9 Error/h
Failure Mode and Effect Analysis
Safety over EtherCAT (Fail Safe over EtherCAT)
File with device-specific data for establishing PROFINET communication
Hardware Failure Tolerance
Category in accordance with EN ISO 13849-1
Output Signal Switching Device, tested signal output
Functional extra-low voltage with safe isolation (Protective Extra Low Voltage)
Performance Level (in accordance with ISO 13849)
Plus−Minus − switched signal paths
Plus−Plus − switched signal paths
PROFIsafe
Pulse width modulation
Safe crawling speed
Safe Digital Input
Safe Digital Output
Safety Extra Low Voltage
Safe Failure Fraction
Safety Integrity Level in accordance with IEC 61508
No protection
Protection against vertically dripping water (dripping
water).
Protection against diagonally falling water (dripping
water), 15 ° compared to normal service position.
Protection against spraying water, up to 60 ° to the ver-
tical
Protection against spraying water from all directions.
Protection against water jets from all directions.
Protection against choppy seas or heavy water jets
(flood protection).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents