Ethernet/Ip - Lenze i550 Series Project Planning Manual

Cabinet 0.25...132 kw
Hide thumbs Also See for i550 Series:
Table of Contents

Advertisement

Product extensions
Networks

EtherNet/IP

EtherNet/IP
EtherNET/IP is a common fieldbus for the connection of inverters to different control systems
in plants.
General information
Design
DC supply of the control electronics
and optional fieldbus
Terminal description
Connection
Connection type
Max. cable cross-section
Max. cable cross-section
Stripping length
Stripping length
Tightening torque
Tightening torque
Required tool
Technical data
Communication profile
Bus terminating resistor
integrated bus terminating resistor
Network topology
Without repeater
With repeater
Station
Type
Max. number
Address
Max. cable length
Max. cable length between two nodes
Process data
Transmit PDOs
Receive PDOs
Cycle time
Switching method
Switch latency
Other data
Communication time
Communication time depends on
222
Optional
Integrated in standard I/O
internally via the inverter
optionally:
External supply
mm²
AWG
mm
inch
Nm
lb-in
EtherNet/IP
AC Drive
not required
No
Tree, star and line
-
Adapter (slave)
254
Station name
m
-
m
100
16 words
16 words
ms
> 4
Store-and-Forward
Cut-Through
µs
~ 125
Additional TCP/IP channel
Processing time in the inverter
Telegram runtime (baud rate, telegram
length)
Nesting depth of the network
Bus load
Mains-dependent
Mains-independent
24 V DC
at X3/24E...GND
EtherNet/IP
X266
RJ45
-
-
-
-
-
-
-
Per subnetwork
Not limited
The length between the nodes is decisive.
max. 32 bits (4 bytes) as a coherent PDO
object
At maximum telegram length
Time between the start of a request and
arrival of the response
EtherNet/IP
X267
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents