Technical Data; Standards And Operating Conditions; Conformities/Approvals; Protection Of Persons And Device Protection - Lenze i550 Series Project Planning Manual

Cabinet 0.25...132 kw
Hide thumbs Also See for i550 Series:
Table of Contents

Advertisement

Technical data

Standards and operating conditions

Conformities/approvals

Conformity
CE
CE
EAC
EAC
RoHS
Approval
UL
UL

Protection of persons and device protection

Enclosure
IP20
Open type
Leakage current
> 3.5 mA AC, > 10 mA DC
Starting current
≤ 3 x rated mains current
Insulation resistance
Overvoltage category III
Overvoltage category II
Control circuit isolation
Safe mains isolation by double/reinforced insu-
lation
Protective measures against
Short circuit
earth fault
Overvoltage
Motor stalling
Motor overtemperature

EMC data

Noise emission
Category C1
Category C2
Category C3
Noise immunity
Meets requirement in compliance with
Actuation on public supply systems
Implement measures to limit the radio interfer-
ence to be expected:
< 1 kW: with mains choke
> 1 kW at mains current ≤ 16 A: without addi-
tional measures
Mains current > 16 A: with mains choke or
mains filter, when sizing for rated power.
2014/35/EU
Low-Voltage Directive
2014/30/EU
EMC Directive (reference: CE-typical drive system)
TR CU 004/2011
Eurasian conformity: safety of low voltage equipment
TR CU 020/2011
Eurasian conformity: electromagnetic compatibility of technical
means
2011/65/EU
Restrictions for the use of specific hazardous materials in electric
and electronic devices
UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 274)
UL 61800-5-1
File No. E132659
EN 60529
Information applies to the mounted and ready-for-use state and
not to the wire range of the terminals
NEMA 250
Protection against contact only according to type 1
Only in UL-approved systems
EN 61800-5-1
Observe regulations and safety instructions!
EN 61800-5-1
0 ... 2000 m a.m.s.l.
EN 61800-5-1
above 2000 m a.m.s.l.
EN 61800-5-1
Earth fault strength depends on the operating status
PTC or thermal contact, I²xt monitoring
EN 61800-3
see rated data
EN 61800-3
see rated data
EN 61800-3
see rated data
EN 61800-3
The machine or plant manufacturer is responsible for compliance
with the requirements for the machine/plant!
EN 61000-3-2
EN 61000-3-2
EN 61000-3-12
Technical data
EMC data
73