Station Assignment - Siemens SIMATIC CC712 Operating Instructions Manual

Industrial ethernet - cloudconnect
Table of Contents

Advertisement

Configuration
4.9 Cloud configuration
"DP4":
{
}
}
4.9.3.3

Station assignment

In this tab, you assign the configured data points to a previously created topic or a group.
Each data point can be linked to exactly one topic/one group.
Assign data points
You can assign the data points to the configured topics or groups consecutively or station-
by-station.
You specify the data point name, data type and other parameters in the data point
configuration, see section Data points (Page 78).
● Select station
Using the drop-down list, you can select the data points of one or all stations. By
selecting a station, you can increase the clarity of the table below.
The table lists all data points that are configured in the stations selected above.
● Data point
Configured name of the data point
● Station
Configured station name
You specify the station name on the "Process access" page, see section Station
configuration (Page 48).
● Data type
Configured data type of the data point
● Topic
⇒ Validity: AWS / Azure / Bluemix / Other Cloud
When entering the name, a drop-down list with topics is shown that starts with the letters
you have entered. Click on an entry to assign the data point.
76
"Value":"Abcd99vE",
"Device":"PLC_1",
"Type":"STRING"
Operating Instructions, 05/2019, C79000-G8976-C503-01
SIMATIC CC712

Hide quick links:

Advertisement

Table of Contents
loading