Operating Conditions: Installation; Installation Instructions - Endress+Hauser Proline Prosonic Flow 90U Technical Information

Ultrasonic flow measuring system; flowrate measurement for standard applications with drinking water, wastewater and process water
Table of Contents

Advertisement

Installation instructions

26

Operating conditions: Installation

Mounting location
Correct measuring is possible only if the pipe is full. Avoid the following mounting locations:
• Highest point of a pipeline. Risk of air accumulating!
• Directly upstream from a free pipe outlet in a down pipe.
(Applies to all sensor versions)
Down pipes
Notwithstanding the above, the installation proposal below permits installation in an open down pipe. Pipe
constrictions or the use of an orifice plate with a smaller cross-section than the nominal diameter prevent the
pipe from running empty while measurement is in progress.
Installation in a down pipe (applies to all sensor versions)
1
Storage tank
2
Measuring sensors
3
Orifice plate, pipe constriction
4
Valve
5
Filling tank
Proline Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W
1
2
3
4
5
A0001103
A0001104
Endress + Hauser

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents