Operating Conditions: Process; Medium Temperature Range; Medium Pressure Range (Nominal Pressure); Pressure Loss - Endress+Hauser Proline Prosonic Flow 90U Technical Information

Ultrasonic flow measuring system; flowrate measurement for standard applications with drinking water, wastewater and process water
Table of Contents

Advertisement

Medium temperature range

Medium pressure range
(nominal pressure)

Pressure loss

32

Operating conditions: Process

• Flowrate measuring sensors Prosonic Flow W (clamp-on):
–20 to +80 °C (optional 0 to +130 °C)
• Flowrate measuring sensors Prosonic Flow U (clamp-on):
–20 to +80 °C
• Flowrate measuring sensors Prosonic Flow W (Insertion):
–40 to +80 °C
• Prosonic Flow C Inline:
Measuring pipe: –10 to +60 °C (epoxy coated)
Flowrate measuring sensors Prosonic Flow W (Inline): –40 to +80 °C
• Sound velocity measuring sensors DDU 18:
–40 to +80 °C
• Wall thickness measuring sensor DDU 19:
0 to +60 °C
• Perfect measurement requires that the static fluid pressure is higher than vapor pressure.
• Max. nominal pressure Prosonic Flow W (insertion): PN 16 (232 psi).
There is no pressure loss.
Proline Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W