Performance Characteristics; Operating Conditions: Installation; Operating Conditions: Environment - Endress+Hauser Proline t-mass 65 Operating Instructions Manual

Thermal mass flow measuring system
Hide thumbs Also See for Proline t-mass 65:
Table of Contents

Advertisement

Proline t-mass 65
Reference calibrating
conditions
Maximum measured error
!
Repeatability
Response time
Installation instructions
Inlet and outlet runs
Length of connecting cable
System pressure
Ambient temperature
!
Storage temperature
Degree of protection
Shock resistance
Vibration resistance
Electromagnetic compatibility
(EMC)
10.1.6

Performance characteristics

• Accredited according to ISO/IEC 17025
• Traceable to National Standards
• Temperature controlled to within ±0.5 °C (± 0.9 °F) at atmospheric pressure and humidity
controlled
Flanged version:
±1.5 % of reading for 100 % to 20 % of full scale at reference conditions
±0.3 % of full scale for 20 % to 1 % of full scale at reference conditions
Insertion version:
±1.5 % of reading plus ±0.5 % of full scale
Note!
• Calibration gas is normally air at reference calibration conditions and with a fully developed flow
profile.
• On site performance is dependant on the standard of installation.
0.5 % for velocities above 0.2 m/s (0.65 ft/s)
Typically less than 2 seconds for 63 % of a given step change (in either direction).
10.1.7

Operating conditions: Installation

see Page 12 ff.
see Page 14 ff.
Max. 100 meters (328 feet), remote version
see Page 23
10.1.8

Operating conditions: Environment

Standard: –20...+60 °C (–4 to +140 °F), available on request –40...+60 °C (–40 °F to +140 °F)
Note!
• Install the device at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
(A protective hood is available on request)
• At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired.
–40...+80 °C (–40 to +176 °F), recommended +20 °C (+68 °F)
Standard: IP 67 (NEMA 4X) for transmitter and sensor
According to IEC 60068-2-31
Acceleration up to 1 g, 10...150 Hz, following IEC 60068-2-6
To IEC/EN 61326 and NAMUR recommendation NE 21
Technical data
87