Endress+Hauser Proline Prosonic Flow 90U Technical Information page 27

Ultrasonic flow measuring system; flowrate measurement for standard applications with drinking water, wastewater and process water
Table of Contents

Advertisement

Proline Prosonic Flow 90U, 90W, 91W, 93C, 93U, 93W
Endress + Hauser
Orientation
Vertical
Recommended orientation with upward direction of flow (View A). Entrained solids sink down. Gases rise
away from the measuring sensor when fluid is not flowing. The piping can be completely drained and protected
against build-up.
Horizontal
In the recommended installation range in a horizontal installation position (View B), gas and air accumulation
at the pipe cover and problematic build-ups at the bottom of the pipe have a minor influence on the
measurement.
A
C = Recommended installation range max. 120° (applies to all sensor versions)
Vibrations
Secure the piping and the Prosonic Flow C Inline sensor if vibration is severe.
Information on resistance to vibration and shock can be found on Page 31
C
B
C
A0001105
> 10 m
A0006103-en
27