Operating Conditions: Installation; Operating Conditions: Environment - Endress+Hauser Proline Promass 83 Operating Instructions Manual

Coriolis mass flow measuring system
Hide thumbs Also See for Proline Promass 83:
Table of Contents

Advertisement

Proline Promass 83 MODBUS RS485
Installation instructions
Inlet and outlet runs
Length of connecting cable
System pressure
Ambient temperature range
!
Storage temperature
Degree of protection
Shock resistance
Vibration resistance
CIP cleaning
SIP cleaning
Electromagnetic compatibility
(EMC)
Endress+Hauser
Promass S, P:
DN
8
15
25
40
50
10.1.7

Operating conditions: Installation

→ Page 14 ff.
There are no installation requirements regarding inlet and outlet runs.
Max. 20 meters (66 feet) (remote version)
→ Page 15
10.1.8

Operating conditions: Environment

Standard: –20 to +60 °C (-4 to +140°F) (sensor, transmitter)
Optional: –40 to +60 °C (-40 to +140°F) (sensor, transmitter)
Note!
• Install the device at a shady location. Avoid direct sunlight, particularly in warm climatic regions.
• At ambient temperatures below –20 °C (–4 °F) the readability of the display may be impaired.
–40 to +80 °C (–40 to +175 °F) (preferably +20 °C (+68 °F))
Standard: IP 67 (NEMA 4X) for transmitter and sensor
According to IEC 68-2-31
Acceleration up to 1 g, 10 to 150 Hz, following IEC 68-2-6
Yes
Yes
To EN 61326/A1 (IEC 1326) and NAMUR Recommendation NE 21
[% o.r./bar]
3/8"
– 0.002
1/2"
– 0.006
1"
– 0.005
1 ½"
– 0.005
2"
– 0.005
Technical data
Promass S
[% o.r./psi]
– 0.0001
– 0.0004
– 0.0003
– 0.0003
– 0.0003
115