(standard version)
Endress + Hauser

Power supply

Connecting power supply and signal cables in the connection compartment
a
b
Connecting the transmitter (wall-mount housing). Cable cross-section: max. 2.5 mm
a
Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC; power consumption: 18 VA / 10 W
Terminal No. 1: L1 for AC, L+ for DC
Terminal No. 2: N for AC, L- for DC
b
Terminals No. 20-27: signal cable
c
Ground terminal for protective earth
d
Ground terminal for signal cable shield
e
Service connector
f
Bolts on connection compartment housing
N (L-)
L1 (L+)
+
1 2
20
21
f
a
c
e
+
+
+
22
23
24
25
26
27
b
d
2
A0001135