Alarm Function; Operation Status At Alarm Occurrence [G] [Wg]; Operation Status At Alarm Occurrence [A] - Mitsubishi Electric MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5 Series:
Table of Contents

Advertisement

3.12

Alarm function

When an error occurs during operation, the corresponding alarm or warning is displayed. When an alarm occurs, ALM
(Malfunction) turns off and the servo motor stops. When a warning occurs, the servo motor may not stop for each warning
number.
The stop method changes depending on whether the forced stop deceleration function is enabled or disabled. However, even
if the forced stop deceleration function is enabled, the forced stop deceleration may not be effective and the servo motor may
stop with the dynamic brake or others, depending on the alarm that has occurred.
After releasing the alarm or warning, resume the operation.
Refer to the following manual for the details of alarms and warnings.
MR-J5 User's Manual (Troubleshooting)

Operation status at alarm occurrence [G] [WG]

The following shows the status of servo amplifiers at alarm occurrence.
Status
The No. of the alarm that has occurred is shown on the 7-segment LED.
When an alarm is detected during operation, the servo motor stops safely with the methods
specified in accordance with the alarm No.
The occurred alarm is recorded as the alarm history. In the alarm history, the latest 16 alarms
are recorded so that the types of alarms that have occurred in the past can be checked.
The conditions of the servo amplifier (such as the servo motor speed and droop pulses)
before/after alarm occurrence are recorded with the drive recorder. This is useful for analyzing
the cause of alarm occurrence.
The ALM (Malfunction) of the output device signal is turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2 or via
a network.

Operation status at alarm occurrence [A]

The following shows the status of servo amplifiers at alarm occurrence.
Status
The No. of the alarm that has occurred is shown on the 7-segment LED.
When an alarm is detected during operation, the servo motor stops safely with the methods
specified in accordance with the alarm No.
The occurred alarm is recorded as the alarm history. In the alarm history, the latest 16 alarms
are recorded so that the types of alarms that have occurred in the past can be checked.
The conditions of the servo amplifier (such as the servo motor speed and droop pulses)
before/after alarm occurrence are recorded with the drive recorder. This is useful for analyzing
the cause of alarm occurrence.
The ALM (Malfunction) and ALMWNG (Malfunction/Warning) of the output device signal are
turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2.
Reference
Refer to "7-segment LED" in the following manual.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
Page 97 Stop method at occurrence of alarms/warnings
Page 96 Alarm history [G] [WG]
Page 184 Drive recorder
Page 96 Alarm history [G] [WG]
Reference
Refer to "Display sequence" in the following manual.
MR-J5-A User's Manual (Introduction)
Page 97 Stop method at occurrence of alarms/warnings
Page 96 Alarm history [G] [WG]
Page 184 Drive recorder
Page 97 Alarm history [A]
3 BASIC FUNCTION
3.12 Alarm function
3
93