Waveform Recording Inapplicable Alarm List; List Of Auxiliary Recording Data - Mitsubishi Electric MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5 Series:
Table of Contents

Advertisement

Waveform recording inapplicable alarm list

Alarms that are not covered in the alarm history are not subject to recording by the drive recorder. For details, refer to the
following manual.
MR-J5 User's Manual (Troubleshooting)
However, the alarms shown in the following table are saved in the alarm history, but are not subject to recording by the drive
recorder. The drive recorder does not operate.
Alarm No.
010.1
012
016
017
019
01A
01E
01F
025
119
When the following alarms occur, data at alarm occurrence may not be recorded depending on its circumstances.
Alarm No.
013
014

List of auxiliary recording data

A list of auxiliary record data saved by the drive recorder is shown.
Instantaneous monitor data
The instantaneous monitor data is saved in the vicinity of the trigger condition establishment.
System configuration display data
The system configuration display data saved by the drive recorder is as follows. Incompatible items are indicated as [----].
Name
Servo amplifier identification information
Servo amplifier serial number
Servo amplifier software number
MAC address
IP address
Motor model
Motor ID
Motor serial number
Encoder resolution
Accumulated power-on time [h]
Num. of inrush cur. sw. times [times]
LED display
Servo parameter
The servo parameters of such as PA, PB, and PC groups are saved in the drive recorder.
Name
Voltage drop in the control circuit power
Memory error 1
Encoder initial communication error 1
Board error
Memory error 3
Servo motor combination error
Encoder initial communication error 2
Encoder initial communication error 3
Absolute position erased
Memory error 4
Name
Clock error
Control process error
Outline
The identification information for the servo amplifier is displayed.
Indicates the serial number of the servo amplifier.
The servo amplifier software number is displayed.
Indicates the MAC address of the servo amplifier.
Indicates the IP address of the servo amplifier.
The model of the servo motor is displayed.
Indicates the servo motor ID.
Indicates the serial number of the servo motor.
The encoder resolution is displayed.
Indicates the power ON cumulative time on an hourly basis [h].
Indicates the number of inrush relay on/off times.
Indicates the contents of the servo amplifier display (LED).
4 APPLICABLE FUNCTION