Mitsubishi Electric MR-J5 Series User Manual page 61

Ac servo system
Hide thumbs Also See for MR-J5 Series:
Table of Contents

Advertisement

■Speed limit value selection
The speed limit can be selected with SP1 (Speed selection 1), SP2 (Speed selection 2), and SP3 (Speed selection 3).
*1
Input device
SP3
SP2
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
*1 0: Off
1: On
When the internal speed 1 to 7 are used to limit a speed, the speed does not vary with the ambient temperature.
■VLC (Limiting speed)
VLC turns on when the servo motor speed reaches a speed limited with internal speed 1 to 7 or analog speed limit.
Speed limit
SP1
0
VLA (Analog speed limit)
1
[Pr. PC05 Internal speed 1]
0
[Pr. PC06 Internal speed 2]
1
[Pr. PC07 Internal speed 3]
0
[Pr. PC08 Internal speed 4]
1
[Pr. PC09 Internal speed 5]
0
[Pr. PC10 Internal speed 6]
1
[Pr. PC11 Internal speed 7]
2 CONTROL MODE