Modbus
Data type /
register
Size in bytes
7892
Unsigned / 2
7919
Unsigned / 2
7963
Unsigned / 2
FCT030 Modbus (From firmware 4.0)
Function Manual, 06/2018, A5E39931813-AB
Parameter
Description
Fraction B flow
Quality sta‐
status
tus code of
the process
value Frac‐
tion B flow
Reference Den‐
Quality sta‐
sity status
tus code of
the process
value Ref‐
erence den‐
sity
Corrected vol‐
Quality sta‐
ume flow status
tus code of
the process
Corrected
value vol‐
ume flow
4.10 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units register)
● Limit status bit 4 & 5:
● 11: Constant
● 01: Low limited
● 10: High limited
● 00: Not limited
● Process data status bit 6 & 7:
● 11: Good
● 01: Poor Accuracy
● 10: Manual / Fixed
● 00: Bad
● Limit status bit 4 & 5:
● 11: Constant
● 01: Low limited
● 10: High limited
● 00: Not limited
● Process data status bit 6 & 7:
● 11: Good
● 01: Poor Accuracy
● 10: Manual / Fixed
● 00: Bad
● Limit status bit 4 & 5:
● 11: Constant
● 01: Low limited
● 10: High limited
● 00: Not limited
● Process data status bit 6 & 7:
● 11: Good
● 01: Poor Accuracy
● 10: Manual / Fixed
● 00: Bad
MODBUS commands
Access
level
Read
only
Read
only
Read
only
67