Siemens SITRANS F Coriolis FCT030 Function Manual page 171

Flowmeters modbus from firmware 4.0
Table of Contents

Advertisement

Process value 2
Table 4-87
Process value 2
Modbus
Data type /
register
Size in bytes
11201
Unsigned / 2
11262
Float / 4
11264
String / 32
11244
Float / 4
11246
String / 32
11205
Unsigned / 2
FCT030 Modbus (From firmware 4.0)
Function Manual, 06/2018, A5E39931813-AB
Parameter
Description
Process value
Process value config‐
ured to be monitored
Maximum value Drag indicator of maxi‐
mum value specified by
Process value (11201)
Maximum value
Shows timestamp of re‐
timestamp
corded maximum value
specified by Process
value (11201)
Minimum value
Drag indicator of mini‐
mum value specified by
Process value (11201)
Minimum value
Shows timestamp of re‐
timestamp
corded minimum value
specified by Process
value (11201)
Reset logging
Command to reset the
drag pointers to the
process value's default
value.
4.10 Modbus holding registers tables
Default value
Value range /
[unit]
Setting options
(unit register)
Disabled
● 3000: Mass flow
● 3002: Volume flow
● 3004: Density
● 3010: Medium
temperature
● 3023: Frame
temperature
● 7950: Corrected
volume flow
● 7871: Fraction A
● 7881: Fraction B
● 7800: Fraction A in %
● 7810: Fraction B in %
● 65535: Disabled
Min. floating
-
point value
[units depend‐
ing on proc‐
ess value]
-
Max. floating
-
point value
[units depend‐
ing on proc‐
ess value]
-
-
-
MODBUS commands
Access
level
Read /
write
Read
only
Read
only
Read
only
Read
only
Write on‐
ly
171