Siemens SITRANS F Coriolis FCT030 Function Manual page 130

Flowmeters modbus from firmware 4.0
Table of Contents

Advertisement

MODBUS commands
4.10 Modbus holding registers tables
Modbus
Data type /
register
Size in bytes
8069
Unsigned / 2
8070
Float / 4
8072
Float / 4
View 5 settings
Table 4-55
View 5 settings
Modbus
Data type /
register
Size in bytes
9016
Unsigned / 2
9011
Unsigned / 2
9030
Unsigned / 2
9031
Unsigned / 2
130
Parameter
Description
Trend log time
Scaling of the time axis.
window
Effective when Trend
scale mode (8068) is
set to 1.
Trend scale low‐
Scaling of the y-axis.
er limit
Lower limit. Effective
when Trend scale
mode (8068) is set to 1.
Trend scale up‐
Scaling of the y-axis.
per limit
Upper limit. Effective
when Trend scale
mode (8068) is set to 1.
Parameter
Description
Enable or disa‐
Enable or disable view. 1
ble
View
Type of appearance.
1
value
Selection of the first val‐
st
ue.
2
value
Selection of the second
nd
value. Depending on
the number of values.
Default value
Value range /
[unit]
Setting options
(unit register)
1
● 0: 1 min
● 1: 5 min
● 2: 15 min
● 3: 30 min
● 4: 1 h
● 5: 2 h
● 6: 3 h
0.0
-
0.0
-
Default value
Value range /
[unit]
Setting options
(unit register)
● 0: Disabled.
● 1: Enabled.
3
● 1: Single value.
● 2: Active diagnostic
events.
● 3: Three values.
● 4: Totalizer.
● 6: 1 value and bar
graph.
● 7: 1 value and graph.
● 8: Six values.
● 9: Six diagnostic
values.
11
See Selectable values
dependent on the view
type (Page 133).
2
See Selectable values
dependent on the view
type (Page 133).
FCT030 Modbus (From firmware 4.0)
Function Manual, 06/2018, A5E39931813-AB
Access
level
Read /
write
Read /
write
Read /
write
Access
level
Read /
write
Read /
write
Read /
write
Read /
write