Figure 2-13: Pick Up Switch
NOTE
Alignment of the pickup switch and magnet wheel is
critical. Improper alignment will cause the acre counter to
record acres erratically or not at all.
6. Attach the short pickup switch ground wire to the
small hole in the 5K714 bracket with a #6-32 x 1/2"
machine screw, removing paint under the wire
connector to assure a good electrical ground
connection.
7. Route the wire from the acre meter down the front of
the seed box to the pickup switch and connect the
mating plugs.
8. Securely fasten the wire to the seed box and
transmission drive, using the adhesive mounting
bases and wire ties to prevent wire from becoming
entangled or rubbing on moving parts.
9. Program the acre counter following the instructions
on See Page 3-18.
ASSEMBLY INSTRUCTIONS
Figure 2-14: Pick Up Switch w/Electric Clutch

Seed Box Dividers

1. Use upper and lower threaded rods and tighten nuts
on each side of original and new dividers.
2. Install dividers over every other hole so that they are
12 inches apart.
3. Procedure same for both 10 foot and 12 foot models.