9.3 Connection

Connection via three-wire cable from ULTRALFOW
Yellow
Signal
Red
Supply
Blue
Ground
Supply
3.6 VDC ± 0.1 VDC
Output when using Pulse Transmitter/Pulse Divider with galvanically separated output module (Y=2)
Type
Open collector. Can be connected as two-wire or three-wire via the built-in pull-up resistance
of 56.2 kΩ.
Diagram 16. Block diagram for galvanically separated output module (Y=2).
Module Y=2
OC and OD
Max input voltage 6 V
Max input current
0,1 mA
ON condition
U ≤ 0,3 V @ 0,1 mA
OFF condition
R ≥ 6 M
5512-385 GB/02.2014/Rev. H1
®
(OB) Kam
30 V
12 mA
U
≤ 2,5 V @ 12 mA
CE
R ≥ 6 M
Table 24
®