4.6 Pulse Divider configuration CCC-DD-E-MMM

Pulse Divider is configured for ULTRAFLOW
duration (E) for the Pulse Divider according to Table 8 and Table 9.
MMM indicates customer label.
q
CCC
p
[m³/h]
[imp/l]
0.6
116
300
0.6
0.6
1.5
119
100
1.5
1.5
1.5
2.5
198
60
2.5
2.5
2.5
3.5
151
50
3.5
3.5
3.5
3.5
6
137
25
6
6
6
6
10
178
15
10
10
10
15
120
10
15
15
15
15
25
179
6
25
25
25
25
Table 8. Configuration options as to meter factor (DD) and pulse duration (E) for
Pulse Divider when connected to ULTRALFOW
®
meter factor (CCC) as well as the required meter factor (DD) and pulse
Meter factor
[l/imp] Divider
DD
1
300
33
2.5
750
63
1
100
33
2.5
250
63
10
1000
34
1
60
33
2.5
150
63
10
600
34
1
50
33
2.5
125
63
10
500
34
25
1250
64
1
25
33
2.5
62.5
63
10
250
34
25
625
64
1
15
33
10
150
34
25
375
64
1
10
33
10
100
34
25
250
64
100
1000
35
1
6
33
10
60
34
25
150
64
100
600
35
5512-385 GB/02.2014/Rev. H1
ULTRAFLOW
Pulse duration
[ms]
[ms] (E=4) [ms] (E=5) [ms] (E=6)
3.9
-
-
20
50
-
-
3.9
-
-
20
50
-
-
-
-
3.9
-
-
20
50
-
-
-
-
3.9
-
-
20
50
-
-
-
-
-
-
3.9
-
-
20
50
-
-
-
-
-
-
3.9
-
-
20
50
-
-
-
-
3.9
-
-
20
-
-
50
-
-
-
-
3.9
-
-
20
-
-
50
-
-
-
-
®
54 or 34, q
0.6...25.
p
®
54 and 34
-
-
Default
100
-
100
-
-
Default
100
-
100
-
100
-
-
Default
100
-
100
-
100
-
-
Default
-
-
100
-
100
-
100
-
-
Default
-
-
100
-
100
-
100
-
-
Default
-
-
100
-
100
-
-
Default
-
-
100
-
100
-
100
Default
-
-
-
-
100
-
100
-
100
13