TECHNICAL DESCRIPTION

9 Calibrating ULTRAFLOW

Calibration can be based on:
Pulses in standard mode
Pulses in test mode
Pulses using PULSE TESTER type 66-99-279
Serial data with the meter in test mode (e.g. used in connection with NOWA)

9.1 Installation

The installation angle must be taken into account installing ULTRAFLOW
Installation. Also see paragraph 9.9 Optimization in connection with calibration.

9.2 Technical data for ULTRAFLOW

®
Output ULTRAFLOW
Type
Output impedance
Pulse duration
Pause
48
®
   
q
Meter factor Flow at 128 Hz
p
[m³/h]
[imp/l]
0.6
300
1.5
100
2.5
60
3.5
50
6
25
10
15
15
10
25
6
40
5
60
2.5
100
1.5
Table 23. Output signal.
Push-Pull
~10 kΩ
2...5 ms
Depending on current pulse frequency
Diagram 15. Block diagram for ULTRAFLOW
5512-385 GB/02.2014/Rev. H1
ULTRAFLOW
. See the restrictions in paragraph 7
[m³/h]
1.54
4.61
7.68
9.22
18.4
30.7
46.1
76.8
92.2
184.3
307.2
®
.
®
54 and 34