Galvanically Separated Output Module (Y=3) - Kamstrup ULTRAFLOW 54 Technical Description

Hide thumbs Also See for ULTRAFLOW 54:
Table of Contents

Advertisement

TECHNICAL DESCRIPTION
8.9.2

Galvanically separated output module (Y=3)

Pulse Transmitter/Pulse Divider is powered by the built-in supply module (Z=2, 7 or 8).
Cable length to Pulse Transmitter/Pulse Divider depends on calculator.
To calculator:
Type:
Open collector.
Connection:
Can be connected as three-wire via the built-in 39.2 kΩ pull-up.
Concerning meter factor and pulse duration, see paragraph 4.6 Pulse Divider configuration CCC-DD-E-MMM.
Diagram 13. Block diagram for galvanically separated output module (Y=3).
Figure 29. Galvanically separated output module (Y=3). Note the omitted components
Module Y=3
Max input voltage 6 V
Max input current
ON condition
OFF condition
Table 22
in the encircled area compared to output module (Y=2).
5512-385 GB/02.2014/Rev. H1
ULTRAFLOW
OC and OD
0,1 mA
U ≤ 0,3 V @ 0,1 mA
R ≥ 6 M
®
54 and 34
43