Kamstrup ULTRAFLOW 54 Technical Description page 39

Hide thumbs Also See for ULTRAFLOW 54:
Table of Contents

Advertisement

TECHNICAL DESCRIPTION
According to DS/EN 1434 the upper flow limit q
periods of time (<1h/day, <200h/year) without exceeding max. permissible errors. ULTRAFLOW
limitations during the period when the meter operates above q
Please note, however, that high flow velocities may cause cavitation, especially at low static pressure. See
paragraph 8.7 Guidelines for dimensioning ULTRAFLOW
q
Meter factor Flow at 128 Hz
p
[m³/h]
[imp/l]
0.6
300
1.5
100
2.5
60
3.5
50
6
25
10
15
15
10
25
6
40
5
60
2.5
100
1.5
Table 19. Flow at max. pulse frequency (128 Hz).
is the highest flow at which the flow sensor may operate for short
s
®
.
5512-385 GB/02.2014/Rev. H1
ULTRAFLOW
[m³/h]
1.54
4.61
7.68
9.22
18.4
30.7
46.1
76.8
92.2
184.3
307.2
.
p
®
54 and 34
®
has no functional
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultraflow 34