Network Configuration; Internal Logic Settings; Fail-Safe Values; Overview - Mitsubishi 700 Series Instruction Manual

Plug-in option. ethernet multiprotocol communication interface
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Password
The password is case-sensitive and can contain letters ("a...z" and "A...Z") and numbers ("0...9").

5.3.2 Network Configuration

The card supports a static IP address. The IP Address, Subnet Mask and Default Gateway fields must
be configured. Please consult with your network administrator for the proper settings of these fields.
5.4

Internal Logic Settings

5.4.1 Fail-safe Values

5.4.1.1

Overview

The card can be configured to perform a specific set of actions when network communications are lost
(timeout event). This allows each inverter parameter to have its own unique "fail-safe" condition in the
event of network interruption. Support for this feature varies depending on the protocol: refer to the
protocol-specific section of this manual for further information.
There are two separate elements that comprise the timeout configuration:
The timeout time
Timeout Object configuration