9.7.2 Read/Write Commands
Table 49 lists the supported commands. Device read/write commands only support 16-bit word access.
Frame
Type
3E/4E
Device Memory Batch Read
3E/4E
Device Memory Batch Write
1E
Device Memory Batch Read
1E
Device Memory Batch Write
9.7.3 Connection Timeout Options
In the studio's Project panel, navigate to A7NETH-2P...Ethernet...MELSEC Client. The following
configuration options will determine the actions to be taken if the connection is abnormally terminated or
lost. While this feature provides an additional level of fail-safe functionality for those applications that
require it, there are several ramifications that must be understood prior to enabling this capability. Note
that a certain degree of caution must be exercised when using the timeout feature to avoid "nuisance"
timeouts from occurring.
Timeout Action
Select an action from the drop down menu:
"None"..................................... No effect. The inverter will continue to operate with the last available
Table 49: MELSEC Client Commands
Command
Name
settings.
PROTOCOL-SPECIFIC INFORMATION
Command
Subcommand
Code
Code
0x0401
0x0000
0x1401
0x0000
0x01
-
0x03
-
Max
Points
719
719
256
256
9
215