4. STARTUP

4.1.2 Wiring check

(1) Power supply system wiring
Before switching on the main circuit and control circuit power supplies, check the following items.
(a) Power supply system wiring
The power supplied to the power input terminals (L1, L2, L3, L11, and L21) of the servo amplifier
should satisfy the defined specifications. (Refer to section 1.3.1.)
(b) Connection of servo amplifier and servo motor
1) The servo amplifier power output (U, V, and W) should match in phase with the servo motor
power input terminals (U, V, and W).
2) The power supplied to the servo amplifier should not be connected to the power outputs (U, V,
and W). Doing so will fail the connected servo amplifier and servo motor.
3) The grounding terminal of the servo motor is connected to the PE terminal of the servo amplifier.
4) The CN2 connector of the servo amplifier should be connected to the encoder of the servo motor
securely using the encoder cable.
5) Between P3 and P4 should be connected.
(c) When you use an option and peripheral equipment
1) 200 V class
a) When you use a regenerative option for 5 kW or less servo amplifiers
The lead wire between P+ terminal and D terminal should not be connected.
The regenerative option should be connected to P+ terminal and C terminal.
A twisted cable should be used. (Refer to "MR-J4-_B_(-RJ) Servo Amplifier Instruction
Manual" section 11.2.4.)
Servo amplifier
U
U
V
V
W
W
Servo amplifier
U
L1
L2
V
W
L3
Servo amplifier
Servo amplifier
P3
P4
4 - 3
Servo motor
M
Servo motor
U
V
M
W
Servo motor
M