Replenishment Pump
Removing the Replenishment Pump
[1]
Disconnect the main power.
[2]
Use PINCH CLAMPS on the TUBING to prevent the solution from draining.
[3]
Disconnect PLUG P19 at J19.
[4]
Remove the MOUNTING SCREWS and the MOTOR.
[5]
Disassemble the PUMP as shown in Figure 43. Replace parts as necessary.
[6]
Reverse the procedure to install the REPLENISHMENT PUMP.
BELLOWS
CONE
RING
246628
Dangerous voltage.
ELBOW
NUT
O-RING
VALVE
VALVE
BODY
O-RING
NUT
CONNECTING
ROD and
BEARING
ASSEMBLY
Figure 43 Removing the Replenishment Pump
CRANK
REPLENISHMENT
PUMP
H048_0037DCB
H048_0037DA
2-39