Selecting Processor Options

Replenishment Mode

7E6174 – 16FEB01
Automatic
Replenishment
Mode
Flooded Replenishment
Mode
Tank Fill Mode
Disable Replenishment Select this feature to disable the Replenisher Pumps
Default Setting
1. Press GO TO SETUP.
PROCESSOR READY
127.4 F = DRYER TEMP
DISPLAY
TIME/
FIX TEMP
DATE
H186_8522AC
Select this mode when you want the Processor to
automatically adjust the Replenishment volumes for
Developer and Fixer according to the Processor film
usage.
Select this mode if your site has low film usage for the
Processor, i.e. less than 25 sheets of 35 x 43 cm (14 x 17
in.) film or equivalent area per 8-hour day. Check with
your Kodak Service Representative to see whether the
Flooded Replenishment Mode is right for the film usage
of the Processor. Replenishment will be added
automatically.
• every 5 minutes, achieving a minimum replenishment
of 780 ml/hr. during Processor operation, and
• when the equivalent film area of 35 x 43 has been
processed.
Select this mode to fill empty Processor tanks
automatically. A warning error stating that the tanks are
currently being filled, occurs as the tanks are filling. After
the tanks are filled, the error is cleared and the Processor
begins with normal operation.
before doing any of the cleaning procedures. When the
Pumps are disabled, a respective error message occurs. To
clear the error, select either Automatic or Flooded
Replenishment.