Link Control; Gsm - EBS CPX200NB Installation And Programming Manual

Alarm control unit
Hide thumbs Also See for CPX200NB:
Table of Contents

Advertisement

8.9. LINK CONTROL

These options allow automatic equipment's response in case the connection with the
monitoring station is lost. It refers to situations when the equipment lost the connection
with GSM network or GPRS transmission is not possible.
8.9.1.

GSM

Activating that function (checking the [Activate] box) allows the access to parameters
defining the equipment's response after leaving GSM network.
You can define after what time from the moment the connection was lost the equipment
shall initiate activities aiming at its restoration. The time is selected in a [Reset after] box
and is defined in minutes.
Then, define what activity shall be initiated by the equipment. Select by checking an
appropriate box at the response description:
 Modem reset
 Device reset
In case the equipment lost the GSM connection, it shall wait for a defined period of time
after the fact was ascertained and then it shall perform stipulated tasks.
CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
85 / 116